| BACK TO PRODUCTS PAGE |
SILOS |
||
WHAT IS A SILO?
IMCS Silos provide an efficient method of storing bulk quantities of
material including plastics, powders, and a variety of dry materials for
process. Not only does bulk storage insure that the materials needed to
keep an operation running are always there, it also provides a way to buy
raw material at less cost. Minimizing waste, contamination, and freeing
up valuable floor space are additional advantages of the IMCS bulk storage
system. IMCS Silos are constructed from an FDA approved galvanized metal
which provides a maintenance free surface. The silos are sealed with FDA
approved crosslinked polyethlene foam sealant to prevent water infiltration.
Various capacities, methods of fill and discharge are available. Accessories
and safety equipment to OSHA specifications, are available to meet customer
needs. |
|
||
STANDARD FEATURES
|
|||
PRODUCT SPECIFICATIONS10° SILO ROOF SYSTEMS30° SILO ROOF SYSTEMS |
|||
INSTALLATION
|
|
||
SILO FOUNDATION SPECIFICATIONS |
|||
Anchor Bolt DetailEvery IMCS silo that we install is mounted to the concrete pad foundation by the Tru-Bolt anchoring system. This eliminates the need for setting bolts in wet concrete before the silo is erected. The Tru-Bolt anchor allows you to erect the silo, position it, and then drill the anchor holes and secure the anchors. With this method, the anchors are always properly located. The Tru-Bolt anchor has a 7800 lb. pull-out strength, exceeding the strength of an ordinary mounting bolt. |
Foundation Specifications
Foundations must be appropriately designed for local soil and frost depth
conditions. Sizes given are adequate to resist 1.5 times the over- turn
force of a 30 psf wind load acting on .6 times the surface area of the silo.
The foundation should be placed on soil with a bearing capacity of 3500
psf, or special modification of the foundation must be considered. Concrete in the footings should have a minimum compression strength of 3,000 psi at 28 days. Reinforcing steel should have a minimum yield strength of 33,000 psi. |
||
|
|||
|
INTERNATIONAL MATERIAL CONTROL SYSTEMS, INC.
510 E. 40th St., Holland,Michigan 49423 1-800-722-5722 Phone / 616-355-2800 Fax / 616-355-2890 Internet / www.imcs-inc.com EMAIL / info@imcs-inc.com |
|||